Fatigue and Fracture Evaluation

I-95
BRI Project - PADOT
Rehabilitation
of Betsy Ross Bridge Interchange ramps, including 58 spans.
The structures contain many transverse box cross girders that are
fracture critical and contain many fatigue sensitive details.
The project requires all these details to be hands-on inspected and
retrofitted if remaining fatigue life is low.
I-95
Restoration (RES) Project - PADOT
Performed
ultrasonic and magnetic particle testing on a steel viaduct.
The results are used to verify the results of a fatigue testing which
includes continuous stress range measurement for three days.
The measured data were reduced to estimate the remaining fatigue life of
the fatigue sensitive details.
Fatigue at Floorbeam to Tied-Girder Connection Angle Evaluation -
ACE
3-D local finite element study for fatigue cracks at
Floorbeam to Tied-Girder Connection Angle of the Chesapeake
City Tied-Arch Bridge.

Remote Health
Monitoring and Load Modeling of Cracked Fracture
Critical Bridge Components - PennDOT